101-01 Guide

Top 10 testing software 101-01 for IT professionals (1 to 10)

we provide Practical Riverbed 101-01 exams which are the best for clearing 101-01 test, and to get certified by Riverbed Riverbed Certified Solutions Associate. The 101-01 Questions & Answers covers all the knowledge points of the real 101-01 exam. Crack your Riverbed 101-01 Exam with latest dumps, guaranteed!

Q1. Which of the following are supported features on the Interceptor appliance running version 2.0.x? (Select 3)

A. EtherChannel

B. Full transparency

C. Port transparency

D. QoS

E. NetFlow

Answer: ABC


Q2. What effect will enable SDR-M (Scalable Data Referencing ­ Memory) have on a Steelhead appliance in production?

A. An increase in overall LAN throughput

B. SDR would occur in RAM until flushed to disk

C. An increase in overall WAN throughput

D. SDR would occur on disk and backed up to RAM for future lookups

E. SDR must occur over the primary interface directly to RAM

Answer: A


Q3. Assuming the Steelhead appliance has a 250 GB datastore capacity, by enabling RSP on a supported Steelhead appliance which of the following would be true:

A. The datastore capacity will shrink due to the amount of space used by RSP

B. The datastore capacity will grow due to the amount of space added by RSP

C. The datastore capacity does not change

D. The datastore capacity will have to be reformatted

Answer: C


Q4. When deploying a Steelhead appliance server-side out-of-path in the data center, which configuration is necessary on the client-side Steelhead appliance in order for the design to function correctly?

A. An auto-discover rule with the IP address of the server-side Steelhead appliance

B. A fixed-target rule with the Primary IP address of the server-side Steelhead appliance

C. A fixed-target rule with the IP address of the destination server

D. No configuration is required

Answer: B


Q5. Which forms of administrative authentication are supported by the Steelhead appliances? (Select 3)

A. NTLM

B. TACACS+

C. RADIUS

D. Kerberos

E. Local username and password

Answer: BCE


Q6. In what file system can the Steelhead Mobile client software be installed?

A. FAT

B. NTFS

C. FAT32

D. UFS

E. EXT3

Answer: B


Q7. An employee who has just installed Steelhead Mobile onto her workstation notices that she never gets any reduction. It always says 0%.

The status of the mobile client appears to Be:

Optimization State: Firewalled

Controller Status: Connected

The reason she is seeing 0% reduction statistics is:

A. Location Awareness is in effect

B. The physical branch Steelhead appliance in her office is behind a firewall

C. The office firewall is stripping the IP options field

D. Her workstation is blocking TCP port 7801

E. The data center is currently firewalling all optimized connections

Answer: D


Q8. When performing a logical in-path deployment, which interface needs to be physically cabled for optimization to occur?

A. LAN

B. AUX

C. WAN

D. Primary

Answer: C


Q9. What is the command to return a Steelhead appliance back to factory defaults?

A. (config) # restart factory reload

B. (config) # reload factory

C. (config) # restart clean

D. (config) # reload clean empty

E. (config) # reset factory reload

Answer: E


Q10. Which of the following is not a policy type available on the CMC appliance?

A. Optimization policy

B. SDR policy

C. Security Policy

D. Networking policy

Answer: B


To know more about the 101-01, click here.

Tagged as : Riverbed 101-01 Dumps, Download 101-01 pdf, 101-01 VCE, 101-01 pass4sure, examcollection 101-01